Abnormal Shutdown of Photovoltaic Inverters: Causes, Impacts, and Proactive Solutions

Why Your Solar Inverter Keeps Shutting Down Unexpectedly
You’ve installed a photovoltaic (PV) system to save energy costs, but suddenly your inverter shuts down without warning. Well, you’re not alone. Over 30% of solar system owners face abnormal inverter shutdowns within the first 5 years of operation, according to the 2024 Global Solar Insights Report. Let’s unpack why this happens and how to fix it.
Common Symptoms of Abnormal Shutdowns
- Sudden power drop to zero on monitoring interfaces (like Huawei’s SmartLogger)
- Error codes: PV insulation resistance low (2021) or DC arc fault (2003)
- Inverter status flipping between "grid-connected" and "fault protection" modes
Error Code | Frequency | Typical Cause |
---|---|---|
2001 | 18% | Excessive PV string voltage |
2003 | 22% | DC arc faults in wiring |
2021 | 15% | Insulation resistance below 50kΩ |
Root Causes Behind Inverter Failures
Environmental Factors
Humidity and dust accumulation account for 40% of shutdowns. For instance, Growsatt inverters often trigger insulation resistance alarms in coastal regions due to saltwater corrosion .
Electrical System Flaws
- Overvoltage scenarios: String configurations exceeding 800V in 3-phase systems
- Grid instability: Voltage spikes above 260V or frequency deviations beyond 50±0.5Hz
“Inverters near grid endpoints face 3x more shutdowns than those close to transformers.” – 2023 IEEE Power Engineering Journal
Hardware Degradation
After 60,000 operational hours, components like IGBT modules and DC capacitors degrade. Huawei’s 2025 field data shows a 12% annual increase in shutdowns for inverters older than 8 years .
Step-by-Step Troubleshooting Guide
Immediate Response Protocol
- Disconnect AC/DC switches (wait 30+ minutes for residual charge dissipation)
- Check insulation resistance:
- Minimum threshold: 2MΩ for PV arrays
- Test method: Megohmmeter at 1000V DC
Advanced Diagnostic Measures
Case Study: A 50kW system in Arizona showed repeated shutdowns. Technicians found:
- String voltage at 850V (vs. 800V max rating)
- Corroded MC4 connectors causing 1.2kΩ resistance spikes
Preventive Maintenance Checklist
- Quarterly:
- Clean heat sinks (dust reduces cooling efficiency by 35%)
- Tighten terminals (torque to 20N·m ±15%)
- Annual:
- Update firmware (critical for arc fault detection algorithms)
- Replace cooling fans (lifespan: 5-7 years)
When to Seek Professional Help
If self-checks don’t resolve the issue, especially with:
- Persistent AFCI (Arc Fault Circuit Interrupter) alarms
- Battery calibration errors in hybrid systems
- Ground fault currents exceeding 30mA
Contact Us
Submit a solar project enquiry,Our solar experts will guide you in your solar journey.