Abnormal Shutdown of Photovoltaic Inverters: Causes, Impacts, and Proactive Solutions

Abnormal Shutdown of Photovoltaic Inverters: Causes, Impacts, and Proactive Solutions | Huijue Group

Why Your Solar Inverter Keeps Shutting Down Unexpectedly

You’ve installed a photovoltaic (PV) system to save energy costs, but suddenly your inverter shuts down without warning. Well, you’re not alone. Over 30% of solar system owners face abnormal inverter shutdowns within the first 5 years of operation, according to the 2024 Global Solar Insights Report. Let’s unpack why this happens and how to fix it.

Common Symptoms of Abnormal Shutdowns

  • Sudden power drop to zero on monitoring interfaces (like Huawei’s SmartLogger)
  • Error codes: PV insulation resistance low (2021) or DC arc fault (2003)
  • Inverter status flipping between "grid-connected" and "fault protection" modes
Error CodeFrequencyTypical Cause
200118%Excessive PV string voltage
200322%DC arc faults in wiring
202115%Insulation resistance below 50kΩ

Root Causes Behind Inverter Failures

Environmental Factors

Humidity and dust accumulation account for 40% of shutdowns. For instance, Growsatt inverters often trigger insulation resistance alarms in coastal regions due to saltwater corrosion .

Electrical System Flaws

  • Overvoltage scenarios: String configurations exceeding 800V in 3-phase systems
  • Grid instability: Voltage spikes above 260V or frequency deviations beyond 50±0.5Hz

“Inverters near grid endpoints face 3x more shutdowns than those close to transformers.” – 2023 IEEE Power Engineering Journal

Hardware Degradation

After 60,000 operational hours, components like IGBT modules and DC capacitors degrade. Huawei’s 2025 field data shows a 12% annual increase in shutdowns for inverters older than 8 years .

Step-by-Step Troubleshooting Guide

Immediate Response Protocol

  1. Disconnect AC/DC switches (wait 30+ minutes for residual charge dissipation)
  2. Check insulation resistance:
    • Minimum threshold: 2MΩ for PV arrays
    • Test method: Megohmmeter at 1000V DC

Advanced Diagnostic Measures

Case Study: A 50kW system in Arizona showed repeated shutdowns. Technicians found:

  • String voltage at 850V (vs. 800V max rating)
  • Corroded MC4 connectors causing 1.2kΩ resistance spikes
Resolution involved reconfiguring strings to 24 panels (720V max) and replacing connectors.

Preventive Maintenance Checklist

  • Quarterly:
    • Clean heat sinks (dust reduces cooling efficiency by 35%)
    • Tighten terminals (torque to 20N·m ±15%)
  • Annual:
    • Update firmware (critical for arc fault detection algorithms)
    • Replace cooling fans (lifespan: 5-7 years)

When to Seek Professional Help

If self-checks don’t resolve the issue, especially with:

  • Persistent AFCI (Arc Fault Circuit Interrupter) alarms
  • Battery calibration errors in hybrid systems
  • Ground fault currents exceeding 30mA
Contact certified technicians for IV curve tracing and insulation resistance mapping.

Contact Us

Submit a solar project enquiry,Our solar experts will guide you in your solar journey.